ACOUSTIC DESIGN MANUAL Cont.


..Sound Transmission Class of Wall Constructions
TSB, when installed in the cavity of a double leaf stud wall can significantly improve the sound reduction achieved by the wall.

Following are examples of the Sound Transmission Class of some building partitions with the different grades of TSB.

Please note the systems referred to are as per the CSR Gyprock Manual.
Sound Estimates: Peter R. Knowland & Assoc.



System A1

  • One layer of 10mm Gyprock Plasterboard
  • 51mm metal studs at 600mm centres
  • One layer of 10mm Gyprock Plasterboard

Cavity infill of:.............STC
TSB 2 .......................38
TSB 3 .......................39
TSB 4 .......................40
TSB 5 .......................42

System A3

  • One layer of 13mm Gyprock Plasterboard
  • 51mm metal studs at 600mm centres
  • Two layers of 13mm Gyprock Plasterboard

Cavity infill of:.............STC
TSB 2 .......................44
TSB 3 .......................45
TSB 4 .......................46
TSB 5 .......................48



System A2

  • One layer of 13mm Gyprock Fyrchek
  • 51mm metal studs at 600mm centres
  • One layer of 13mm Gyprock Fyrchek

Cavity infill of:.............STC
TSB 2 .......................40
TSB 3 .......................41
TSB 4 .......................42
TSB 5 .......................44

System A4

  • Two layers of 13mm Gyprock Fyrchek
  • 51mm metal studs at 600mm centres
  • Two layers of 13mm Gyprock Fyrchek

Cavity infill of:.............STC
TSB 2 .......................46
TSB 3 .......................47
TSB 4 .......................48
TSB 5 .......................50



System A6

  • 1 x 13mm CSR Gyprock
  • 64mm metal studs at 600mm centres
  • 1 x 13mm CSR Gyprock

Cavity infill of:.............STC
TSB 2 .......................43
TSB 3 .......................44
TSB 4 .......................46
TSB 5 .......................47

System A6

  • 2 x 13mm CSR Gyprock
  • 64mm metal studs at 600mm centres
  • 1 x 13mm CSR Gyprock

Cavity infill of:.............STC
TSB 2 .......................46
TSB 3 .......................47
TSB 4 .......................49
TSB 5 .......................50


More - Sound Transmission Class of Wall Constructions