Product Description
Applications
Standard Sizes & Packing
Physical Properties
Performance Data
Testing
Quality Assured
AS/NZS ISO 9002 1994
Approved by BVQI
Certificate 19875
Back to
Index page

|
 |
Tontine AcoustiFoam
D A T A S H E E T

Tontine AcoustiFoam is a flexible foam insulation material manufactured from polyester polyurethane.
The product comes as a dark grey foam.
Tontine AcoustiFoam is ideal for use as a non-reflective surface to absorb airborn noise.
Tontine AcoustiFoam can be readily combined with other more dense materials to help reduce noise transmission and
vibration problems. Typical applications are in commercial building, industrial and automotive situations.
..Standard Sizes & Packing |
Product |
Sizes (mm)
|
Approx. Roll Length (M)
|
TAF 6mm
TAF 12mm
TAF 25mm
TAF 50mm |
6 x 1400
6 x 2100
12 x 1400
12 x 2100
25 x 1400
25 x 2100
50 x 1400
50 x 2100
|
164
164
82
82
39
39
17
17
|
Density:
Tear Resistance:
Tensile Strength:
Elongation:
Resilience:
Compression Set (75%):
Cell Count per 25mm:
Indentation Force Deflect IFD at 40%:
Indentation Factor: |
28kg /m3 - 30kg/m3
520 N/m Minimum
175 kPa Minimum
350% Minimum
20% Minimum
15% Maximum
55 +/- 5
165 +/- 20
1.79 |
Tontine AcoustiFoam has been tested to the following flammability standards:
.Standard |
Description |
Result
|
F.A.R 25.853/App.F |
Vertical Burn Test for Aircraft components. |
PASS
|
FMVSS302 & SAE T2002 |
Flammability test for automotive components. The horizontal flame spread
rate is measured. |
PASS
|
UL94 |
Horizontal flame spread test on foam piece as manufactured and after heat
ageing. |
PASS
|
AS 1530.3 |
Test for early fire hazard properties of material. |
PASS
|
Tontine AcoustiFoam
Test Method: AS 1935 (Acoustic Impedance Tube)
.Product |
Frequency |
|
250Hz
|
500Hz
|
1000Hz
|
2000Hz
|
4000Hz
|
TAF 12mm
TAF 25mm
TAF 50mm |
0.07
0.14
0.23
|
0.12
0.33
0.61
|
0.25
0.76
0.92
|
0.76
0.80
0.81
|
0.76
0.76
0.97
|

The above graph is given for customers guidance only. Acoustic properties of TAF may vary according to batch
and the test method.
All testing was conducted in a laboratory situation. On site results may vary due to site conditions and quality
of installation. As these products are constantly being researched and developed, we reserve the right to update
these specifications without notice.
|