Properties, Rod Johnston stated the following: The comments below deal principally with wall and ceiling linings, which are covered by Specification C1.10a. This specification provides a Deemed-to-Satisfy solution for providing suitable performance in respect of fire hazard properties. In the absence of clear quantified performance requirements of fire hazard properties, Specification C1.10a becomes the de-facto definition of fire hazard performance requirements for floor materials, floor coverings, wall and ceiling linings. The principal thrust of Specification C1.10a. is to define Critical Radiant Flux for floor materials and floor coverings and Group Number for walls and ceilings. The Group Number is derived from physical testing to AS ISO 9705; or prediction in accordance with Clause 3 of Specification A2.4. This requires testing to AS/NZS 3837. Testing of assemblies is covered by AS/NZS 1530.3 and AS 1530.4. The conclusions are;
|