FRL 240/240/240 Concrete Protection - Intubatt by FIREFLY![]() Protecting Concrete Structures ![]() DTS System FRL240/240/240 tested in accordance with AS1530.4-2014, and assessed in accordance with AS4072.1-2005, Warringtonfire Report No: FAS210074 RIR. This is a report from an accredited testing laboratory that meets Specification A2.3, Section 2(c) of NCC2016 Amendment 1 (including prior versions), and Schedule 5, Section 2(c) of NCC2019 (including Amendment 1) for the determination of an FRL. Current potential issues for some building stock in Australia:
I believe that this may be a serious non-compliance issue, due to the fact that Table 5.5.2(A) is sometimes overlooked in some fire-engineered solutions. This means that an FRP90/90/90 or FRP120/120/120 cannot be determined in accordance with AS3600 if the floor slab is less than 200mm thick. Therefore the only route to compliance is via a DTS Tested System FRL. ![]() Retrofit Solution Install one layer of FIREFLY™ Intubatt® to the underside of the slab to achieve a DTS FRL240/240/240. The same applies for where the slab may be 200mm thick and designed for a building which originally only required an FRP90/90/90 or FRP120/120/120, or FRL90/90/90 or FRL120/120/120 which has since had a change of use and the FRP or FRL needs to be higher. For Retrofit & New Build Benefits of the FIREFLY™ Intubatt® concrete slab DTS Tested System:
Installation Instructions Step 1 ![]() Either run a bead of TBA Firefly™ Intumastic around the perimeter of the TBA Firefly™ Intubatt®, nominally 50mm in from the edge, then a cross from corners to corners, or directly onto the ceiling instead. Step 2 ![]() Paint all green edges of the TBA Firefly™ Intubatt® with TBA Firefly™ Intumastic Brush Grade. Step 3 ![]() Secure the TBA Firefly™ Intubatt® using M6.5 x 100mm long hex head masonry screws and 30mm OD x 1.5mm thick, steel penny washers. Installed @ 50mm from each corner and 50mm from the edge. 6 x fixings per full 1200mm x 600mm sheet. 4 x fixings per 600mm x 600mm or smaller. Step 4 ![]() The TBA Firefly™ Intubatt® must be installed in a staggered brick type pattern. If any green can be seen on the joints, paint over with TBA Firefly™ Intumastic Brush Grade. The fixings and washers do NOT require painting over. TBA Firefly™ Products
If you're a structural engineer, fire engineer, architect, designer, builder, or building certifier/surveyor, please feel free to contact our office to obtain a copy of the Warringtonfire Compliance Report: FAS210074 RIR.
|
(02) 8004 3333 (Press Option 2) 44 Gindurra Road, Somersby NSW 2250
|