Product Description
Applications
Standard Sizes & Packing
Physical Properties
Performance Data
Sample Specification
Testing

Quality Assured
AS/NZS ISO 9002 1994
Approved by BVQI
Certificate 19875
Back to
Index page

|
 |
Tontine Sound Batts
D A T A S H E E T

Tontine Sound Batts are made of polyester, which inherently does not absorb moisture and will not
break down. It remains in a safe, clean, hygienic state, thereby not contributing to sick building syndrome.
Tontine Sound Batts are ideal for use in walls and partitions, where they provide excellent acoustic and thermal
performance. Refer to the Acoustic Design Manual to determine which Tontine Sound Batt
will provide the best result to meet your requirements.
..Standard Sizes & Packing |
Product |
Sizes (mm)
|
No. per pack
|
TSB 2
TSB 3
TSB 4
TSB 5 |
16.5 x 610
2700 x 610
15m x 610
2700 x 610
15m x 610
2700 x 610
10m x 610
2700 x 610
|
2 rolls
12 batts
2 rolls
10 batts
2 rolls
10 batts
2 rolls
10 batts
|
Melting Point:
Vapour Pressure:
Per Cent Volatiles:
Specific Gravites:
Flash Point:
Flammability:
Other Properties:
Ingredients:
Max Service Temp:
Alkalinity:
Moisture Absorption: |
250 degrees C.
Not Applicable.
Nil.
1.38.
Not Applicable.
Complies with Building Code of Aust.
Non-allergenic, low irritant, resilient.
Organic, Long chain polyester polymer.
150 degrees C.
pH 7.8 (pH 7 is neutral).
Exposure to an atmosphere of 50 C & 95%RH for four days gives a moisture absorption of less than 0.2% by volume. |
|
TSB 2 |
TSB 3 |
TSB 4 |
TSB5 |
Nominal Thickness (mm)
Thermal Conductivity (W/m.K)@23°C
STC*
NRC
R-Value (m2K.W) |
50
0.061
43
-
0.8 |
65
0.061
44
0.50
1.0 |
75
0.062
46
0.65
1.2 |
85
0.060
47
0.70
1.4 |

* STC tests carried out by Challis and Associates Pty Ltd (TSB 2-5), using 13mm plasterboard
each side of a 64mm stud frame with 600mm centres. Results in other wall structures available on request.
The insulation material shall be polyester TSB (2,3,4 or 5)..mm thick as manufactured by Tontine Fibres. The batt
shall be fitted in one piece per stud opening to fill the entire area.
All testing was conducted in a laboratory situation. On site results may vary due to site conditions and quality
of installation. As these products are constantly being researched and developed, we reserve the right to update
these specifications without notice.
|