D A T A S H E E T


..Product Description
Tontine Sound Batts are made of polyester, which inherently does not absorb moisture and will not break down. It remains in a safe, clean, hygienic state, thereby not contributing to sick building syndrome.


..Applications
Tontine Sound Batts are ideal for use in walls and partitions, where they provide excellent acoustic and thermal performance. Refer to the Acoustic Design Manual to determine which Tontine Sound Batt will provide the best result to meet your requirements.


..Standard Sizes & Packing
Product

Sizes (mm)

No. per pack

TSB 2


TSB 3


TSB 4


TSB 5

16.5 x 610
2700 x 610

15m x 610
2700 x 610

15m x 610
2700 x 610

10m x 610
2700 x 610

2 rolls
12 batts

2 rolls
10 batts

2 rolls
10 batts

2 rolls
10 batts



..Physical Properties
Melting Point:
Vapour Pressure:
Per Cent Volatiles:
Specific Gravites:
Flash Point:
Flammability:
Other Properties:
Ingredients:
Max Service Temp:
Alkalinity:
Moisture Absorption:
250 degrees C.
Not Applicable.
Nil.
1.38.
Not Applicable.
Complies with Building Code of Aust.
Non-allergenic, low irritant, resilient.
Organic, Long chain polyester polymer.
150 degrees C.
pH 7.8 (pH 7 is neutral).
Exposure to an atmosphere of 50 C & 95%RH for four days gives a moisture absorption of less than 0.2% by volume.


..Performance Data

  TSB 2 TSB 3 TSB 4 TSB5
Nominal Thickness (mm)
Thermal Conductivity (W/m.K)@23°C
STC*
NRC
R-Value (m2K.W)
50
0.061

43
-
0.8
65
0.061

44
0.50
1.0
75
0.062

46
0.65
1.2
85
0.060

47
0.70
1.4


* STC tests carried out by Challis and Associates Pty Ltd (TSB 2-5), using 13mm plasterboard each side of a 64mm stud frame with 600mm centres. Results in other wall structures available on request.


..Sample Specification
The insulation material shall be polyester TSB (2,3,4 or 5)..mm thick as manufactured by Tontine Fibres. The batt shall be fitted in one piece per stud opening to fill the entire area.


..Testing
All testing was conducted in a laboratory situation. On site results may vary due to site conditions and quality of installation. As these products are constantly being researched and developed, we reserve the right to update these specifications without notice.