Screen Injection for Deep Ventilation Shaft from NeofermaNeoferma proposed a screen injection solution for a deep ventilation shaft at a pumping station located in Bahrain's Northern districts, near the seafront in Manama. This shaft, measuring 30 meters in depth and 25 meters in length, provided essential airflow for the pumping station. Due to its proximity to the sea, the water table was high, and the shaft had been cast against a pile wall. Conventional methods, including joint and crack injections using Polyurethane resins, proved ineffective in halting leaks across the surface. Recognizing the challenge, Neoferma's technical team recommended the installation of an acrylic screen between the pile wall and the concrete wall. Subsequently, the wall was meticulously drilled and injected with Neoferma's Acryl-X 1000.
The results were remarkable, with leakage completely eradicated following the injection. Additionally, control holes were strategically implemented to facilitate the maintenance of resin flow. For further insights into the successful utilization of the non-toxic Acryl-X 1000 in the screen injection project for the deep ventilation shaft by Neoferma, we invite you to explore our website at neoferma.com.
|
Neoferma Australia Pty Ltd Profile 07 5576 4922 West Burleigh, Qld, 4219 Shop Neoferma Australia Pty Ltd
|