Spec-Net Building Index
FIREFLY

Fire Rated Roof Sarking from FIREFLY

roof sarking application

PHOENIX EA SARKING

Phoenix EA is a lightweight, waterproof sarking, foil faced on one side.

CERTIFICATION
Tested for both vertical and horizontal applications

AS1530.4
BRANZ Report Number FAR2701

AS1530.2-1993 Flammability Test
AWTA Report Number 7-576926-CN

AS4200.1-1994 Clause 6.1.3
AS1301.448s -1991
AS/NZS 4200.1-1994 Table 1 (Extra Heavy Duty)
Number: 7-577747-CN
AS/NZS4201.4-1994 (PASS)
AS/NZS4200.1-1994 CLAUSE 6-4 (High)
AWTA Report

Full compliance to AS3959-2009 Extra Heavy
Duty Sarking for BAL-12.5<BAL40

FRL-/90/-

UNIT OF MEASURE - Roll

SIZE 25m x 1m = 25m2

WEIGHT 560g per m2 THICKNESS 1mm

APPLICATIONS
Phoenix EA extra heavy duty sarking is used to wrap the outside of timber or steel roof and wall frames to provide superior protection against mild to severe ember attack during bush fires. In addition to it's flammability index of 1 it has a Fire Rating Level of -/90/- when tested to AS1530.4 (Method for fire tests on building materials, components and structures).