Royal North Shore Hospital Redevelopment and Community Health Service Project.
The Wolfin GWSK Waterproofing Membrane System has been installed on the critical areas of the Royal North Shore Hospital - over the electrical and plant areas on the Emergency Entrance & Main Ambulance Driveway.
The membrane itself was terminated within the walls of the hospital - where it
acts as a cavity flashing.

The Wolfin membrane system continues under the block façade to form the cavity flashing
Site Specific Detailing:
Where the decorative poles are, steel plates where pre-installed in-situ into the
slab, metal rods were then welded to the steel plates. A square section of Wolfin
GWSK membrane was then installed and detailed to each extruded rod with
standard Wolfin ring patches. The poles were then installed and fixed into place,
and again, 100mm of membrane extended out past the plate perimeters to be
connected onto at a later date.

Decorative poles are bolted to the planter floors with SS booker rods chemically anchored into the concrete and sealed with the Wolfin system
Planter Box W/PD The Wolfin Way:
The garden beds were also waterproofed using the Wolfin System (FLL Test-
Certified Root Proof).
The horizontal membrane was pre-installed and protected to where the block
work planter boxes were to be installed, to enable the brick layers to carry out
their works and build their walls directly over the membrane, including detailing
each individual starter bar. Again, the membrane is protected and extended
100mm past the walls to be connected!onto at a later date.
Non Mechanical Fixing of Wolfinsteel Terminations:
In regards to the steel curved planter box, no fixings were to be visible when
fixing the Wolfin profiles in place, this is where the Projex Group special
adhesive, Wolfinator, came into its own, as the Wolfin applicators were able to
adhere the profiles to the curved steel planter walls with the Wolfinator
adhesive.
Wolfinator was also used to fix the Wolfinsteel profiles to the steel "H" frame
support columns for the covered glass walkway. As the frames where welded to
pre-installed in-situ plates in the concrete the Wolfin membrane needed to be
carried up and around the columns to create a watertight termination for the
membrane. A special profile order was placed with the suppliers Projex Group,
for a flat 100mm Wolfinsteel section so that the profile of the columns could be
matched. (Wolfinsteel Profiles can be made to order)
The Wolfin membrane system can be effectively sealed to awkward shapes. In
situations where the Wolfin system cannot be mechanically fastened to the
substrate (steel, glass, fibreglass etc) the Wolfinsteel is adhered to the substrate
with Wolfinator, a construction grade
adhesive.

The Wolfin membrane system is sealed to the steel 'H' columns that support the covered walkways.
Once all trades had completed their works the remaining areas were primed.
The fibrous cement sheet protection previously installed over the membrane
extensions were removed and the balance of Wolfin GWSK direct-stick
membrane was installed, connecting onto the previously installed membrane to
the perimeters, planter boxes, extruded poles and "H" frames.
In areas where concrete was to be installed over the completed membrane,
5mm thick Projex Shockmat was laid over the membrane as a protection matting
prior to the placement of the reinforcing steel. Asphalt was laid directly onto the
Wolfin GWSK Membrane on all the remaining deck areas.
The perimeter curbing was installed over the Wolfin membrane to ensure that
the waterproofing of the deck area continued to its extremities without
jeopardising the integrity of the waterproofing system.
Installation of the Wolfin Waterproofing System More Critical Areas

Anchor points for concrete curbing and islands have been detailed & waterproofed using standard Wolfin installation procedures. Over 3,500 square metres of Wolfin were used in this area.

Wolfin IB is welded directly to PVC pipes
The Wolfin membrane has been welded directly to the PVC rainwater and
wastewater service pipes and outlets and terminated into the concrete columns
to ensure the integrity of the waterproofing to all areas.
Wolfin QA & Inspections
At all completed stages of the works, and prior to the areas being handed over
to the Builder's relevant trades, each completed section was inspected by a
(Wolfin Membranes Australia) inspector and Quality Assurance sheets were
issued and forwarded to the Builder.
The Wolfin System was installed by GBA Waterproofing, a Licensed Wolfin
Applicator.
Wolfin Membrane Systems have been installed on many hospitals in Australia. In
Sydney the installations include St George Private Hospital, Prince of Wales
Hospital, Sydney Childrens Hospital, Royal Hospital for Women, Liverpool
Hospital and Royal Prince Alfred Hospital.